Part F

  • Diagram 1 Provisions for background ventilation

  • Diagram 2a Ventilation systems

  • Diagram 2b Single sided ventilation

  • Diagram 3 Two habitable rooms treated as a single room for ventilation purposes

  • Diagram 4 A habitable room ventilated through a conservatory

  • Diagram 4 Spaces for access

  • Diagram C1 Ground floor flat plan

  • Diagram C2 Semi-detached ground floor plan example

  • Diagram C3 Semi-detached house first floor plan example

  • Table 5.1a Extract ventilation rates

  • Table 5.1b Whole dwelling ventilation rates

  • Table 5.2a System 1- background ventilators and intermittent extract fans (for additional Information see Table 5.3 and worked examples C1 and C5 in Appendix C)

  • Table 5.2a System 1- background ventilators and intermittent extract fans (for additional Information see Table 5.3 and worked examples C1 and C5 in Appendix C)

  • Table 5.2a System 1- background ventilators and intermittent extract fans (for additional Information see Table 5.3 and worked examples C1 and C5 in Appendix C) continued

  • Table 5.2b System 2- Passive Stack Ventilation (PSV) (for additional information see table 5.3 and worked examples C2 and C6 in Appendix C)

  • Table 5.2b System 2- Passive Stack Ventilation (PSV) (for additional information see table 5.3 and worked examples C2 and C6 in Appendix C) continued 2

  • Table 5.2c System 3- Continuous mechanical extract (MEV)(for additional information see Table 5.3 and worked examples C3 and C7 in Appendix C)

  • Table 5.2c System 3- Continuous mechanical extract (MEV)(for additional information see Table 5.3 and worked examples C3 and C7 in Appendix C) continued

  • Table 5.2d System 4- Continuous mechanical supply and extract with heat recover (MVHR)(for additional information see Table 5.3 and worked examples C4 and C8 in Appendix C)

  • Table 5.2d System 4- Continuous mechanical supply and extract with heat recover (MVHR)(for additional information see Table 5.3 and worked examples C4 and C8 in Appendix C) continued

  • Table 5.3 Performance Test Methods

  • a href="http://cms.thebuildingregulations.org.uk/wp-content/uploads/2016/04/Table-5.2b-System-2-Passive-Stack-Ventilation-PSV-for-additional-information-see-table-5.3-and-worked-examples-C2-and-C6-in-Appendix-C-continued.png" rel="attachment wp-att-7884">

  • Table 6.1a Extract ventilation rates

  • Table 6.1b Whole building ventilation rate for air supply to offices

  • Table 6.2a ventilation for offices with natural air supply - ventilation provisions

  • Table 6.2b Ventilation for offices with natural air supply - location of ventilators in rooms

  • Table 6.2c Ventilation for offices with natural air supply - controls for ventilators in rooms

  • Table 6.3 Ventilation of other buildings and spaces

  • Table 6.3 Ventilation of other buildings and spaces

  • Table A1 Surface Water Activity

  • Table A2 Indoor air relative humidity

  • Example C1 Background ventilators and intermittent extract fans (this is based on Table 5.2a)

  • Example C2 Passive stack ventilation (this is based on Table 5.2b)

  • Example C3 Continuous mechanical extract (this is based on Table 5.2c)

  • Example C4 Continuous mechanical supply and extract with heat recovery (this is based on Table 5.2d)

  • Example C5 Background ventilators and intermittent extract fans(this is based on Table 5.2a)

  • Example C6 Passive stack ventilation (this is based on Table 5.2b)

  • Example C7 Continuous mechanical extract (this is based on Table 5.2c)

  • Example C8 Continuous mechanical supply and extract with heat recovery (this is based on Table 5.2d)

  • Table D1 Guidance on ventilation intake placement for minimising ingress of pollutants